DMX512 REFERENCE GUIDE 3
Cable/Connector Terminology
This manual uses American wire gauge (AWG) measurements when describing cables and connectors. For use in
countries outside the U.S., or for assembling compatible cables, consult the AWG/Metric Conversion Table given
below for the appropriate metric equivalent.
CAUTION: Although maximum rated currents are 225A and 35A, we recommend that continuous operating
current does not exceed 150A and 20A respectively.
Other common terms used when describing cables and/or connectors are as follows:
European mains cable sizes [single core rubber insulation (HO-7RN-F)] are measured in cross-sectional square
millimeters. Commonly available sizes are 35 mm
2
(∼150 Amp), 70 mm
2
(∼250 Amp), and 95 mm
2
(∼300 Amp).
AWG Metric Max Rated Current
2/0
67.5 mm
2
225A
8/5
8.37 mm
2
(5 x 6.0 mm
2
)
35A
Term Definition
plug male connector
receptacle female connector
Hubbell connector 5-pin, three phase connector (8/5)
Epic connector 6-pin, three phase connector (8/5)
Cam-Lok connector single pole connector (2/0)