Rate
The Rate feature speeds up or slows down the playback of events (cues or effects).
The Rate encoder allows a percentage adjustment from 0-999 with 999% being the fastest rate and 0% causing the
event to stop.
+ The default is 100%, which is real time (5 seconds = 5 seconds).
+ Decrease the percentage to slow down the event (50% rate applied to 5 seconds = 10 seconds).
+ Increase the rate percentage to speed up the event (200% rate applied to 5 seconds = 2.5 seconds).
Guidelines:
+ All timing values associated with an event (luminaire delay and times, cue out time, waits and trails) are affected
by the rate modification proportionally.
+ If a cue is complete, the rate adjustment will affect the pending cue. When the pending cue is activated, the
adjusted rate is used to determine timing.
To set rate mode using submaster touchscreen:
Step 1. Choose a submaster to bring up its Setup options. ("Choose" is activated by touching the specific
submaster on the touchscreen.)
Step 2. Using touchscreen, select
Rate checkbox.
Step 3. Press
Closeto close Setup screen.
Step 4. Use Rate encoder to adjust rate to required value.