LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 1
Refer to the QuickLIT Web site for the most up-to-date version of this document.
Applications
The LN Series Free Programmable LN-PRGxxx-12
Controllers are microprocessor-based and designed to
control various building automation systems, such as
multi-zone air handing units, lighting control, central
plant applications, and power measurement
applications.
The LN Free Programmable Controllers are built on a
similar platform, but have different numbers of inputs
and outputs. The LN PRG6x0-12 controllers are
compatible with the LN Input/Output (I/O) Extension
Module 400 Series models. For more information on
LN I/O Extension Modules, refer to LN Series Input/
Output (I/O) Extension Modules Installation Instructions
(LIT-12011693).
The LN Free Programmable Controllers use the
L
ONWORKS® communication protocol.
Follow these recommendations for proper installation
and subsequent operation of each controller:
Inspect the controller for shipping damages. Do not
install damaged controllers.
Keep the controller at room temperature for at least
24 hours prior to installation to allow any
condensation that may have accumulated during
shipping to evaporate.
If the controller is used in a manner not specified
by Johnson Controls, the functionality and the
protection provided by the controller may become
impaired.
Record the 12-digit Neuron® ID located on either
end of the device (shown on the sticker below the
barcode) for commissioning.
Note: The controller’s plastic enclosure has a
back plate that is separate from the front plate
allowing the back plates to be shipped directly to
the installation site while all the engineering is done
elsewhere.
North American Emissions Compliance
Canada
United States
Installation
Observe these guidelines when installing an LN Free
Programmable Controller:
Transport the controller in the original container to
minimize vibration and shock damage.
Verify that all parts shipped with the controller.
Do not drop the controller or subject it to physical
shock.
IMPORTANT: Prevent any static electric discharge
to the controller. Static discharge can damage the
controller and void the warranties.
Industry Canada Statement
The term IC before the certification/registration
number only signifies that the Industry Canada
technical specifications were met.
Le terme « IC » précédant le numéro d'accréditation/
inscription signifie simplement que le produit est
conforme aux spécifications techniques d'Industry
Canada.
This equipment has been tested and found to
comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when this equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference, in which case the
users will be required to correct the interference at
their own expense.
LN Series Free Programmable LN-PRGxxx-12 Controllers
Installation Instructions
LN-PRG203-12, LN-PRG300-12,
LN-PRG4x0-12, LN-PRG6x0-12
Code No. LIT-12011796
Issued April 24, 2014
Supersedes January 30, 3013
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Installation Instructions

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 1 Refer to the QuickLIT Web site for the most up-to-date version of thi

Strany 2 - Dimensions

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions10Output Wiring RecommendationsOutput wiring recommendations include:• F

Strany 3 - Mounting

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 11Voltage OutputsConnect the 0 to 10 VDC as shown in Figure 29. If y

Strany 4 - Identification

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions12Subnetwork Communications Wiring with the LN-PRG6x0-12 ControllerSuppo

Strany 5 - Controller Jumper Location

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 13Connecting the Wireless ReceiverConnect the wireless receiver to the

Strany 6 - LN SVSENx

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions14MaintenanceEach controller requires minimal maintenance, but it is imp

Strany 7 - Input Wiring

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 15Network Traffic Query node statistic to check errors.Use a LONWORKS

Strany 8

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions16Status LED Operation For further information on the LN Series Communic

Strany 9 - Output Wiring

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 17Technical Specifications LN-PRG203-12 (Part 1 of 2

Strany 10

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions18Outputs Digital (Triac) Outputs: 5Universal Outputs: 3Digital: 24 VAC

Strany 11 - Communications Wiring

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 19LN-PRG300-12 (Part 1 of 2)Product Code LN-PRG300-12Power Requirement

Strany 12 - Wireless Installation

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions2Dimensions Figure 1: LN-PRG203-12 and LN-PRG300-12 Controller Dimen

Strany 13

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions20Outputs Universal Outputs: 8Universal Output Characteristics: 0-10 VDC

Strany 14

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 21LN-PRG4x0-12 Series (Part 1 of 2)Product Code LN-PRG400-12, LN-PRG41

Strany 15 - ONWORKS

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions22Outputs Universal Outputs: 12Universal Output Characteristics: 0-10 VD

Strany 16 - ONWORKS data bus

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 23Environmental Operating Temperature: 0 to 50°C, (32 to 122°F)Storage

Strany 17 - LN-PRG203-12 (Part 1 of 2)

Published in U.S.A. www.johnsoncontrols.comLN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 24Metasys® and Johnson Cont

Strany 18 - LN-PRG203-12 (Part 2 of 2)

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 3MountingLocation ConsiderationsObserve these guidelines when mounting

Strany 19 - LN-PRG300-12 (Part 1 of 2)

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions4Power WiringWe recommend wiring only one controller per 24 VAC transfor

Strany 20 - LN-PRG300-12 (Part 2 of 2)

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 5Figure 6: LN-PRG300-12 Controller Jumper Locations* Factory-default p

Strany 21 - °C [77°F])

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions6 Figure 8: Typical Power and Network Connections with an LN-SVSENx-0 In

Strany 22 - °C (68°F)

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 7Input WiringThe controllers have physical connections for inputs, whi

Strany 23

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions8Use the Figure 14 configuration for a 3-wire, 0 to 20 mA transducer pow

Strany 24

LN Series Free Programmable LN-PRGxxx-12 Controllers Installation Instructions 9 LN Series Communicating Sensors WiringThe LN Communicating Sensor

Komentáře k této Příručce

Žádné komentáře